D. Locating Your New Unit
The following conditions should be considered when selecting a location for your
unit:
1. Floor load - The area on which the unit will rest must be free of vibration and
suitably strong enough to support the combined weights of the unit plus the maximum
product load weight, which are provided in the table below:
MODEL
CUBIC
FT
FACTOR
WEIGHT
POUNDS
TOTAL
CAPACITY
MODEL
CUBIC
FT
FACTOR
WEIGHT
POUNDS
TOTAL
CAPACITY
2030F 69 35 840 3255
2010R 24 35 345 1185
2030PR 69 35 750 3165
2011FR 24 35 345 1185
2135R 31 35 800 1885
2020F 47 35 620 2265
2168R 66 35 1205 3515
2020FPR 47 35 570 2215
2235R 31 35 830 1915
2020P 47 35 595 2240
2010D 12/10 35 495 1265
2021F 47 35 620 2265
2. Clearance - There must be a combined total of at least 3" clearance on all sides of
the unit.
3. Ventilation - The air cooled self contained unit requires a sufficient amount of cool
clean air. Avoid placing the unit near heat generating equipment such as ovens,
ranges, heaters, fryers, steam kettles, etc. and out of direct sunlight. Avoid
locating the unit in an unheated room or where the room temperature may drop below
55° F or above 90° F.
12